Showing posts with label University of Adelaide. Show all posts
Showing posts with label University of Adelaide. Show all posts

Friday, May 11, 2018

Porous-core photonic crystal fibers guide polarization-preserving terahertz waves






Highly birefringent and near-zero dispersion-flattened photonic crystal fibers guide terahertz waves for applications in low-loss imaging and sensing.
Photonic crystal fibers (PCFs), also known as microstructured optical fibers (MOFs), are a distinct class of optical fibers that are particularly suited to applications in the fields of sensing, biomedical imaging, time domain spectroscopy, security, DNA hybridization and cancer detection, and in optical communications. Unlike conventional optical fibers, PCFs provide high birefringence and controllable chromatic dispersion.
Solid-core PCFs experience large material loss that is not suitable for terahertz signal transmission, while hollow-core PCFs limit electromagnetic waves to short propagation distances and have high bending losses that are inversely proportional to the diameter and bending radius of the fiber. Because these undesirable features have slowed the acceptance of solid and hollow-core PCFs, porous-core fibers have been developed.
Our team at the University of Adelaide focuses on porous-core PCFs that contain an engineered number of microstructured air holes in the core, allowing the designer to control such global fiber parameters as air hole size, pitch distance (center-to-center distance between air holes), core diameter, and air-hole shape. In turn, operational parameters such as effective material loss, birefringence, dispersion, confinement loss, numerical aperture, and other modal properties can be obtained by design as dictated by application requirements.
PCFs as waveguides
The main function of a waveguide is to transmit electromagnetic radiation with the lowest possible transmission loss and near-zero dispersion at the desired wavelength. Over the last decade, a number of waveguide structures have been designed and studied for efficient and reliable transmission of electromagnetic waves.

FIGURE 1. Photonic crystal fiber (PCF) designs proposed to reduce transmission loss of electromagnetic (and especially terahertz) waves include a hybrid core in a regular hexagonal cladding (a), a hybrid core in a modified hexagonal cladding (b), a rotated hexagonal core in a circular cladding (c), and a diamond-shaped core in a kagome cladding (d).
FIGURE 2. Highly birefringent PCF-based waveguides include a kagome cladding with elliptical air-hole core (a), a kagome cladding with rectangular air-hole core (b), and a rectangular air-hole cladding with an array of elliptical air holes in the core (c).

Initially, terahertz electromagnetic waves were guided by metallic waveguides. The various types of metallic waveguides included circular, parallel-plate, bare-metal wire, and slit waveguides. Unfortunately, metallic waveguides face a number of problems, including the fact that metal strips and slots create large Ohmic and attenuation losses; circular metallic waveguide substrates incur high dielectric losses; beam spreading in the unguided media cause divergence losses in parallel- plate waveguides; and radiative losses in the bare metallic waveguide occur because of weak confinement of the mode to the structure. A better option for terahertz transmission is the optical fiber dielectric waveguide.
Reducing transmission loss
Considering the advantage of PCFs, a number of waveguide structures have been designed for low-loss transmission of electromagnetic waves (see Fig. 1).
Dramatic reduction of the material absorption loss caused by the bulk material used in the background of a PCF is possible through (a) a hexagonal cladding and hybrid structured core; (b) a modified hexagonal cladding in which the air holes from each edge are removed, reducing loss and improving birefringence; (c) a circular-clad PCF waveguide with rotated hexagonal core; and (d) a kagome-clad PCF that reduces confinement loss 3–4X more than other competing PCF structures.





The latter kagome configuration reduces loss by a factor of 3–4X more than the other reported cladding structures. The reason being that kagome cladding has the ability to constrict more light inside the core and restrict light from going further towards the cladding.
High birefringence
For polarization-preserving applications, PCFs need to have asymmetry between the x- and y-polarization modes. As such, a number of asymmetrically structured waveguides have been proposed to obtain high birefringence, including elliptical and rectangular air holes inside a kagome lattice (see Fig. 2).
These elliptical and rectangular air holes in the core create large asymmetry between the x and y polarization mode, thus improving the birefringence. Note that it is also possible to generate birefringence using circular-shaped air holes—however, that also requires a structure that generates asymmetry between the polarization modes.
Birefringence and sensing
By replacing the ambient air in the holes of a PCF with various analytes, a PCF can be converted to a sensor. Sensitivity is improved by optimizing the modified total internal reflection (MTIR) mechanism of the PCF to improve the interaction of light with the surrounding PCF substrate materials.
For example, if we use water (refractive index of approximately 1.33) as an analyte inside the core hole instead of air (refractive index around 1.0), the light interaction with the analyte will be stronger because of strong MTIR due to the higher refractive index of the core than the cladding. In essence, core power fraction is increased and confinement loss is decreased. Note that relative sensitivity is proportional to core power fraction and therefore, as core power fraction increases, the relative sensitivity also increases (see Fig. 3).


FIGURE 3. Examples of PCFs used as sensors include a suspension-type cladding with porous core (a) and a rectangular airhole cladding with hollow core (b).
FIGURE 4. Standard deviation in optical constants is compared to sample thickness. The optimum thicknesses, where the standard deviation is minimal, are indicated by arrowheads. By moving towards a thicker sample, the standard deviation rapidly increases to the point comparable to the optical constants’ values. The standard deviation at high frequency is more sensitive to the thickness increment, as the terahertz-ray magnitude at high frequencies is relatively low.
FIGURE 5. A PCF-based surface plasmon resonance biosensor can be used in external sensing (a) or internal sensing (b) configuration.

So, why is PCF birefringence necessary for sensing?Considering ethanol as the chemical analyte, experiments show that measurement uncertainty increases with sample thickness because terahertz waves, when used as the interrogation wavelength, suffer increased absorption. However, if sample thickness is reduced too much, uncertainty also increases because of an insufficient interaction depth, so there is a tradeoff between these extremes and an optimal thickness can be calculated (see Fig. 4).
It has been proven that the optimal sample thickness to minimize measurement uncertainty is (2/α), where α is the absorption coefficient. Note that the absorption coefficient for ethanol is in the 20–80 cm-1 range in the 0.2–1.4 THz band. If you consider α= 20 cm-1, this will yield the worst-case largest thickness of 2/α= 2/20 = 0.1 cm = 1 mm.
Although 1 mm is a rather-large thickness value, the minima in the uncertainty vs. thickness curves are not narrow, but reasonably flattened—that is, halving the optimal thickness does not significantly degrade the uncertainty. As a result, we can reasonably halve the value of 1 mm and select 0.5 mm as a suitable sample thickness. When this 0.5 mm sample is then analyzed at around 1.4 THz, the path length of terahertz radiation is now effectively 0.05 × 80 = 4 absorption lengths. This corresponds to a 20 log e^-4 ∼=-35 dB attenuation, which is manageable.
Fiber-based terahertz heterodyne detection is known to be possible at power levels as low as 3 μW. This means that the input terahertz power into the fiber must be >160 μW, which is perfectly achievable. Because it is also well known that fiber-based heterodyne detection requires the polarization of the local oscillator to be aligned to the polarization being detected at the end of the fiber, polarization-preserving fibers must be used, solidifying the need for birefringence in PCF fiber-based terahertz sensing.
PCF sensor comparison
Characterizations of both porous-core and hollow-core PCFs for sensing show that hollow cores can improve performance in that more analytes can fill the core structure.3In a sensor structure with a suspension type cladding with a circular-air-hole based porous core, the core interfaces can create issues with sensing, depending on the glass materials used.
There is also the option in PCF sensing of using an external or an internal sensing mechanism (see Fig. 5). In an external sensing approach, the analyte channel is outside the plasmonic material and is relatively easy to fill. Conversely, an internal sensing approach with the analyte within the air holes is more complicated because filling microstructured tiny air holes with an analyte is difficult.
Using the surface plasmon resonance (SPR) effect between the metal and dielectric interface of a PCF can also create a SPRbased biosensor. By incorporating such metals as gold, copper, iron, and silver within the fiber core, SPR works when the electrons of the p-polarized light waves oscillate between the metal-dielectric interfaces. A tiny change of environmental refractive indices shifts the resonance wavelengths, enabling extremely sensitive SPR sensors for medical diagnostics and testing, antigen-antibody interactions, environmental monitoring, homeland security, and food safety.4
To date, PCF fabrication methods such as capillary stacking, drilling, and sol-gel methods create circular holes, while 3D printing, extrusion, and chemical vapor deposition (CVD) methods create noncircular and complex structures. As these methods improve, next-generation PCF designs will continue to progress in both sensing and transmission applications.

Wednesday, February 7, 2018

The future of wireless communications is terahertz


Electrical and optical engineers in Australia have designed a novel platform that could tailor telecommunication and optical transmissions. They experimentally demonstrated their system using a new transmission wavelength with a higher bandwidth capacity than those currently used in wireless communication. Reported this week in APL Photonics, these experiments open up new horizons in communication and photonics technology. Here, a schematic of the problem: Aperture in a metallic screen with a dielectric fiber placed on top acting as a magnetic dipole emitter when excited by a wave incident on the aperture. Credit: Andrey E. Miroshnichenko

 https://phys.org/news/2018-02-future-wireless-terahertz.html#jCp

Electrical and optical engineers in Australia have designed a novel platform that could tailor telecommunication and optical transmissions. Collaborating scientists from the University of New South Wales in Sydney and Canberra, the University of Adelaide, the University of South Australia and the Australian National University experimentally demonstrated their system using a new transmission wavelength with a higher bandwidth capacity than those currently used in wireless communication. Reported this week in APL Photonics, these experiments open up new horizons in communication and photonics technology.

Optical fibers are the frontrunners in fast data transmission, with data encoded as . Microwave  is a type of electromagnetic radiation with longer wavelengths, and therefore lower frequencies, than visible light. Current microwave wireless networks operate at a low gigahertz frequency bandwidth. In our current digital age that demands speedy transmission of large amounts of data, the limitations of microwave bandwidths become more increasingly more apparent.

In this study, scientists examined  radiation, which has shorter wavelengths than microwaves and therefore has higher bandwidth capacity for data . Furthermore, terahertz radiation provides a more focused signal that could improve the efficiency of communication stations and reduce power consumption of mobile towers. "I think moving into  will be the future of wireless communications," said Shaghik Atakaramians, an author on the paper. However, scientists have been unable to develop a terahertz magnetic source, a necessary step to harness the magnetic nature of light for terahertz devices.
The researchers investigated how the pattern of terahertz waves changes on interaction with an object. In previous work, Atakaramians and collaborators proposed that a magnetic terahertz source could theoretically be produced when a point source is directed through a subwavelength fiber, a fiber with a smaller diameter than the radiation wavelength. In this study, they experimentally demonstrated their concept using a simple setup—directing terahertz radiation through a narrow hole adjacent to a fiber of a subwavelength diameter. The fiber was made of a glass material that supports a circulating electric field, which is crucial for magnetic induction and enhancement in .
"Creating terahertz magnetic sources opens up new directions for us," Atakaramians said. Terahertz magnetic sources could help the development of micro- and nanodevices. For example, terahertz security screenings at airports could reveal hidden items and explosive materials as effectively as X-rays, but without the dangers of X-ray ionization.
Another advantage of the source-fiber platform, in this case using a magnetic terahertz source, is the proven ability to alter the enhancement of the terahertz transmissions by tweaking the system. "We could define the type of response we were getting from the system by changing the relative orientation of the source and fiber," Atakaramians said.
Atakaramians emphasized that this ability to selectively enhance radiation isn't limited to terahertz wavelengths. "The conceptual significance here is applicable to the entire electromagnetic spectrum and atomic radiation sources," said Shahraam Afshar, the research director. This opens up new doors of development in a wide range of nanotechnologies and quantum technologies such as quantum signal processing.

Monday, February 22, 2016

OT-Stretchable nano-devices put smart contact lenses in sight


https://blogs.adelaide.edu.au/eleceng-announcements/2016/02/21/stretchable-nano-devices-put-smart-contact-lenses-in-sight/
by David Bowler
Researchers at the University of Adelaide and RMIT University have joined forces to create a stretchable nano-scale device to manipulate light.
The device manipulates light to such an extent that it can filter specific colours while still being transparent and could be used in the future to make smart contact lenses.
Using the technology, high-tech lenses could one day filter harmful optical radiation without interfering with vision – or in a more advanced version, transmit data and gather live vital information or even show information like a head-up display.
The light manipulation relies on creating tiny artificial crystals termed “dielectric resonators”, which are a fraction of the wavelength of light – 100-200 nanometers, or over 500 times thinner than a human hair.
The research combined the University of Adelaide researchers’ expertise in interaction of light with artificial materials with the materials science and nanofabrication expertise at RMIT University.
Dr Withawat Withayachumnankul, from the University of Adelaide’s School of Electrical and Electronic Engineering, said: “Manipulation of light using these artificial crystals uses precise engineering.
“With advanced techniques to control the properties of surfaces, we can dynamically control their filter properties, which allow us to potentially create devices for high data-rate optical communication or smart contact lenses.
“The current challenge is that dielectric resonators only work for specific colours, but with our flexible surface we can adjust the operation range simply by stretching it.”
Associate Professor Madhu Bhaskaran, Co-Leader of the Functional Materials and Microsystems Research Group at RMIT, said the devices were made on a rubber-like material used for contact lenses.
“We embed precisely-controlled crystals of titanium oxide, a material that is usually found in sunscreen, in these soft and pliable materials,” she said.
“Both materials are proven to be bio-compatible, forming an ideal platform for wearable optical devices.
“By engineering the shape of these common materials, we can create a device that changes properties when stretched. This modifies the way the light interacts with and travels through the device, which holds promise of making smart contact lenses and stretchable colour changing surfaces.”
Lead author and RMIT researcher Dr Philipp Gutruf said the major scientific hurdle overcome by the team was combining high temperature processed titanium dioxide with the rubber-like material, and achieving nanoscale features.
“With this technology, we now have the ability to develop light weight wearable optical components which also allow for the creation of futuristic devices such as smart contact lenses or flexible ultrathin smartphone cameras,” Gutruf said.
The work, which has been published in leading micro-/nano-science journal ACS Nano, is supported by the Australian Research Council.

Abstract-A. Ebrahimi, Miniaturised-elements frequency selective surfaces for microwave and terahertz applications,18th February 2016.


https://blogs.adelaide.edu.au/eleceng-announcements/2016/02/10/a-ebrahimi-miniaturised-elements-frequency-selective-surfaces-for-microwave-and-terahertz-applications18th-february-2016/

Frequency selective surfaces (FSSs) are usually formed by two-dimensional periodic arrangement of metallic elements on a dielectric substrate. Based on the geometry and arrangement of the metallic unit cell, the array might show different functionalities such as bandpass or bandstop spatial filter. The FSS functionality is mainly determined by its unit cell geometry and dimension. In terms of the unit cell properties, the FSSs can be divided into two major subclasses as: (i) Traditional FSSs based on resonant element unit cells, (ii) miniaturised elements FSSs based on non-resonant unit cells.
In this talk, we will present our recent research results on the design of high-performance FSSs based on miniaturised elements. The miniaturised element FSSs are considered for tunable microwave FSSs. The application of the miniaturised elements in designing a second-order bandpass terahertz FSS will also be presented and discussed.

Biography:

Amir Ebrahimi received the B.Sc. degree in electrical and computer engineering from the University of Mazandaran, Iran, in 2008, and the M.Sc. degree in electronic engineering with first class honours from Babol University of Technology, Babol, Iran. From2009 to 2012, hewas a research assistant in Integrated Circuits Research Laboratory (ICRL), Babol University of Technology. In 2012, he started his PhD degree in the School of Electrical & Electronic Engineering, The University of Adelaide. During 2014–2015, he was a visiting scholar in the School of Electrical & Electronic Engineering, Nanyang Technological University (NTU), Singapore.
During his candidature, Mr Ebrahimi received a number of awards and scholarships including, the International Postgraduate Research Scholarship (IPRS) by the Australian Government (2012), Australian Postgraduate Award (APA) (2012), Australian National Fabrication Facility (ANFF) award for fabricating high performance microwave microfluidic sensors in collaboration with the Ian Wark Research Institute, University of South Australia (2013), the University of Adelaide D. R. Stranks Traveling Fellowship (2014), the Simon Rockliff Scholarship for outstanding postgraduate mentorship from DSTO (2015), and the Yarman-Carlin best student paper award at the Mediterranean Microwave Symposium, Lecce, Italy (2015). Mr Ebrahimi has served as a reviewer for a number of recognised journals including IEEE Microwave and Wireless Components Letter, IEEE Sensors Journal, Applied Physics Letters, and Journal of Applied Physics.

Thursday, July 11, 2013

Trapping T-rays for better security scanners



                                          A concept design of the silicon-based metamaterial. 
                                          Credit: Dr Daniel White, ScienceFX
http://phys.org/news/2013-07-t-rays-scanners.html
(Phys.org) —Medical diagnostic and security scanners with higher sensitivity could result from University of Adelaide research into detecting T-rays (terahertz waves).

Read more at: http://phys.org/news/2013-07-t-rays-scanners.html#jCp


Published in the journal Advanced Optical Materials, the researchers describe a novel structure which traps terahertz waves in tiny (micro-scale) holes to produce much higher contrast imaging than currently possible.
Terahertz waves, which are with frequencies between those used for mobile and for optical fibre communications, are used for some airport and other security scanners to see through packages and clothes. They are also capable of distinguishing malignant from healthy tissues for cancer detection

This work takes an unconventional path to detecting terahertz waves," says Dr Withawat Withayachumnankul, project leader and ARC Postdoctoral Fellow in the University's School of Electrical and Electronic Engineering.


Dr Withayachumnankul has worked with RMIT University in Melbourne and Albert Ludwigs University of Freiburg in Germany to produce the new structure using metamaterials (materials that show non-natural properties with the use of carefully engineered structures).
The structure is made of tiny (micro-scale) cavities etched into the surface of silicon. Terahertz waves that hit the structure are captured and compressed inside the cavities.
"By tailoring the silicon properties through the use of micro-structures (the size of a cross-section of human hair) it is possible to trap and confine the waves in a volume much smaller than the wavelength of the terahertz ," says Dr Withayachumnankul.
"This significantly improves the efficiency of terahertz devices such as scanners and will have broad impact on biomedicine and homeland security, where better contrast means more accurate identification."
RMIT team leader Dr Sharath Sriram says: "We needed to carefully select appropriate materials and processes to produce this device. We couldn't construct the micro-cavities in our first choice of material so we changed to silicon which we had to adapt to make it slightly electrically conductive. We then used established silicon microfabrication techniques to create the micro-cavities, exploiting the conductive properties."
The new structure could be added to conventional terahertz imaging devices to enhance their performance.