Showing posts with label Jie Wang. Show all posts
Showing posts with label Jie Wang. Show all posts

Tuesday, August 4, 2020

Abstract-Single-cell terahertz spectral characteristics in simulated scattering near-field imaging mode


Jie Wang, Shihan Yan, Zaoxia Li, Ziyi Zang, Xingxing Lu, and Hong-Liang Cui

Schematic of the coupled tip–cell model system.
https://www.osapublishing.org/osac/abstract.cfm?URI=osac-3-8-2096

Spectral imaging of a single cell with terahertz (THz) wave is valuable in determination of its physiological state for cell-based precision diagnosis, as THz photon energy is in tune with the vibration-rotation and conformation related excitations of cellular material, and THz absorption is extremely sensitive to the state and degree of hydration of a cell. Because of the severe mismatch between the cell size and the THz wavelength, such imaging has to be carried out in the near-field modality. To make the design and performance assessment of a THz near-field spectral imager effective and systematic, we simulate the scattering THz near-field signals of tumor cells by strictly controlling cell model parameters with representative physiological states. The results demonstrate that the specific physiological characteristics from intracellular hydration state, nucleocytoplasmic ratio, and cell geometric morphology of tumor cells can be characterized quantitatively by their discrepant dielectric response in the THz band, correlating THz near-field scattering signal from a cell with the latter’s corresponding physicochemical state.
© 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

Saturday, April 20, 2019

Abstract-Significant enhancement of THz detectivity by lowering ZnTe crystal temperature in electro-optic sampling



Xuewei Ju, Deren Chen, Xingchen Chen, Tao Gao, Ying Chen, Jie Wang, Xiangfeng Wang

Fig. 1. (a) Experimental setup 1, in which ZnTe was placed in a cryostat as a detection…

https://www.sciencedirect.com/science/article/pii/S0925346719301831

The temperature of the ZnTe detection crystal in a THz time-domain system was tuned continuously from 300 K to 1.5 K to minimize phonon absorption, thus enhance its detectivity. The THz peak amplitude was observed to increase more than 10 times. To explain this phenomenon, the THz transmission spectra of the ZnTe crystal at different temperatures were also measured, and the refractive indexand absorption coefficient of the crystal were extracted. The experiments and theoretic analysis reveal that the significant detectivity enhancement is due to the reduced absorption of the THz field and phase matching change in the detection crystal with temperature decreasing, which makes the ZnTe crystal suitable for integrating with cryogenic applications.

Saturday, June 9, 2018

Abstract-Imidazolium-grafted graphene oxide via free radical polymerization: An efficient and simple method for an interpenetrating polymer network as electrolyte membrane


  • Amina Ouadah, 
  • Tianwei Luo, 
  • Jing Wang, 
  • Shuitao Gao, 
  • Xing Wang, 
  • Xin Zhang, 
  • Zhou Fang, 
  • Zeyu Wu, 
  • Jie Wang, 
  • Changjin Zhu, 



  • In this work, graphene oxide (GO) is modified via free radical polymerization with butylvinylimidazolium (b-VIB) to produce GO/IM, which is characterized using FTIR spectral analysis, X-ray diffraction (XRD), thermogravimetric analysis (TGA), Raman analysis, X-ray photoelectron spectroscopy (XPS), elemental analysis, and a morphology study with transmission electron microscopy (TEM) and scanning electron microscopy (SEM). Further, GO/IM is incorporated for an in-situ polymerization, with the synthesized copolymer para-methyl styrene/butylvinylimidazolium (PMS/b-VIB) and synthesized poly(4,4′-diphenyl ether-5,5′-bibenzimidazole) (DPEBI) as a matrix, giving nanocomposite membranes referred to as GO/IM-X. These nanohybrid membranes possess higher conductivity than the pristine membrane of PMS/b-VIB/DPEBI and the conductivity increases with increasing amount of GO/IM, reaching 78.5 mS cm−1 at 100 °C and 26.5 mS cm−1 25 °C (chloride conductivity), enhancements of about 14.93% and 33.16% compared to the pristine membrane. Nanocomposite membrane properties were investigated; the swelling ratio and water uptake, ion exchange capacity (IEC), thermal properties via TGA, structure characterization using FTIR, morphology via TEM and mechanical properties. Taken together, these results suggest the present nanohybrid membranes have great potential for use as polymer electrolyte membranes with fuel cell applications.