Showing posts with label J.A. Woollam. Show all posts
Showing posts with label J.A. Woollam. Show all posts

Saturday, December 31, 2016

Abstract-Screening effects in metal sculptured thin films studied with terahertz Mueller matrix ellipsometry


  • a Department of Physics and Optical Science, University of North Carolina at Charlotte, Charlotte, U.S.A
  • b Department of Electrical and Computer Engineering, University of Nebraska-Lincoln, Lincoln, U.S.A.
  • c Department of Physics, Chemistry and Biology (IFM), Linköping University, Linköping, Sweden
  • d J.A. Woollam Co. Inc. 645 M Street, Suite 102, Lincoln, NE 68508, U.S.A.

http://www.sciencedirect.com/science/article/pii/S0169433216329324

The anisotropic optical dielectric functions of a metal (cobalt) slanted columnar thin film deposited by electron-beam glancing angle deposition are reported for the terahertz (THz) frequency domain before and after the slanted columnar thin film was passivated by a conformal alumina coating. A simple effective medium dielectric function homogenization approach which describes isolated, electrically conductive columns rendering the thin film biaxial (orthorhombic) is used to model the observed optical responses. Upon passivating the slanted columnar thin film with a 3 nm thick alumina film an increase of both the real and the imaginary part of the dielectric function for all major polarizability directions is found and attributed to screening effects within the spatially coherent metal nanocolumns.

Wednesday, January 22, 2014

Abstract-An integrated mid-infrared, far-infrared and terahertz optical Hall effect instrument


We report on the development of the first integrated mid-infrared, far-infrared and terahertz optical Hall effect instrument, covering an ultra wide spectral range from 3 cm
−1 to 7000 cm−1 (0.1-210 THz or 0.4-870 meV). The instrument comprises four sub-systems, where the magneto-cryostat-transfer sub-system enables the usage of the magneto-cryostat sub-system with the mid-infrared ellipsometer sub-system, and the far-infrared/terahertz ellipsometer sub-system. Both ellipsometer sub-systems can be used as variable angle-of-incidence spectroscopic ellipsometers in reflection or transmission mode, and are equipped with multiple light sources and detectors. The ellipsometer sub-systems are operated in polarizer-sample-rotating-analyzer configuration granting access to the upper left 3×3 block of the normalized 4×4Mueller matrix. The closed cycle magneto-cryostat sub-system provides sample temperatures between room temperature and 1.4 K and magnetic fields up to 8 T, enabling the detection of transverse and longitudinal magnetic field-induced birefringence. We discuss theoretical background and practical realization of the integrated mid-infrared, far-infrared and terahertz optical Hall effect instrument, as well as acquisition of optical Hall effect data and the corresponding model analysis procedures. Exemplarily, epitaxial graphene grown on 6H-SiC, a tellurium doped bulk GaAs sample and an AlGaN/GaN high electron mobility transistor structure are investigated. The selected experimental datasets display the full spectral, magnetic field and temperature range of the instrument and demonstrate data analysis strategies. Effects from free charge carriers in two dimensional confinement and in a volume material, as well as quantum mechanical effects (inter-Landau-level transitions) are observed and discussed exemplarily.