Showing posts with label Peng Wang. Show all posts
Showing posts with label Peng Wang. Show all posts

Saturday, December 14, 2019

Abstract-Enhancement of Intracavity-Pumped Terahertz Parametric Oscillator Power by Adopting Diode-Side Pumped Configuration Based on KTiOPO4 Crystal




Feilong Gao, Xingyu Zhang ,Zhenhua Cong,Zhaojun Liu,Xiaohan Chen,Zengguang Qin,Peng Wang,Jinjin Xu,Zecheng Wang, Na Ming

 https://www.mdpi.com/2073-4352/9/12/666/htm

In this paper, a KTiOPO4 (KTP) crystal is used as the nonlinear medium in an intracavity-pumped terahertz parametric oscillator (TPO) based on stimulated polariton scattering (SPS). Almost all the reported intracavity SPS sources adopt the diode-end pumped configuration, and the THz output power is limited by the serious thermal effect and small fundamental beam size. For improving the THz output power, we propose diode-side pumping for the laser medium to get a higher fundamental power and a larger fundamental beam size. A convex–plane fundamental laser resonator is used to further offset the thermal effect and increase the fundamental beam size. The THz frequency of the intracavity-pumped KTP terahertz parametric oscillator can be discontinuously tuned from 3.19 THz to 5.94 THz with three gaps. The fundamental beam diameter in the KTP crystal is about 1.3 mm. The maximum average THz power is 166 μW at 5.74 THz under a pulse repetition frequency (PRF) of 6 kHz and a diode pump power of 98 W. By means of the diode-side pumped configuration, the maximum THz output power is more than two-fold higher compared to the diode-end pumped configuration reported using the KTP crystal.

Wednesday, February 27, 2019

Abstract-Terahertz oscilloscope for recording time information of ultrashort electron beams



Lingrong Zhao, Zhe Wang, Heng Tang, Rui Wang, Yun Cheng, Chao Lu, Tao Jiang, Pengfei Zhu, Long Hu, Wei Song, Huida Wang, Jiaqi Qiu, Roman Kostin, Chunguang Jing, Sergey Antipov, Peng Wang, Jia Qi, Ya Cheng, Dao Xiang, and Jie Zhang

https://journals.aps.org/prl/accepted/d407dY16M5819b51b9d98708b359b7042e3e658c9

We propose and demonstrate a Terahertz (THz) oscilloscope for recording time information of an ultrashort electron beam. By injecting a laser-driven THz pulse with circular polarization into a dielectric tube, the electron beam is swept helically such that the time information is uniformly encoded into the angular distribution that allows one to characterize both the temporal profile and timing jitter of an electron beam. The dynamic range of the measurement in such a configuration is significantly increased compared to deflection with a linearly polarized THz pulse. With this THz oscilloscope, nearly 50-fold longitudinal compression of a relativistic electron beam to about 15 fs (rms) is directly visualized with its arrival time determined with 3 fs accuracy. This technique bridges the gap between streaking of photoelectrons with optical lasers and deflection of relativistic electron beams with radio-frequency deflectors, and should have wide applications in many ultrashort electron beam based facilities.

Friday, September 7, 2018

Abstract-Highly Conductive, Mechanically Strong Graphene Monolith Assembled by Three-Dimensional Printing of Large Graphene Oxide


Jianhua Ma, Peng Wang, Lei Dong, Yingbo Ruan, Hongbin Lu



https://www.sciencedirect.com/science/article/pii/S002197971831018X#!

The manufacturing of three-dimensional (3D) graphene monolith with high mechanical and electrical performance has become an urgent issue in view of their potential applications in energy and electronics fields. Due to the structure rigidity and poor liquid-phase processing capability of graphene sheets, it is challenging to fabricate 3D graphene monolith with high mechanical performance, including strength, toughness and resiliency. Graphene oxide (GO) shows an improved dispersibility and reduction-restorable conductivity, which enables it to effectively balance the processing and comprehensive performances of graphene monolith. Here, we demonstrate a strategy to fabricate high-performance, shape-designable 3D graphene monolith through a 3D printing method based on large-sized graphene oxide (LGO) fluid ink. The concentration of the LGO ink for printing is as low as 20 mg/mL. The resulting monolith exhibits low density (12.8 mg/cm3), high electrical conductivity (41.1 S/m), high specific strength (10.7×103 N·m/Kg) and compressibility (up to 80% compressive strain). Such a 3D printing technique enables plenty of complicated monolith structures and broadens the application range of graphene.

Sunday, August 26, 2018

Abstract-Dual-model analysis for improving the discrimination performance of human and nonhuman blood based on Raman spectroscopy



Haiyi Bian, Peng Wang, Ning Wang, Yubing Tian, Pengli Bai, Haowen Jiang, and Jing Gao

https://www.osapublishing.org/boe/abstract.cfm?uri=boe-9-8-3512

The discrimination accuracy for human and nonhuman blood is important for customs inspection and forensic applications. Recently, Raman spectroscopy has shown effectiveness in analyzing blood droplets and stains with an excitation wavelength of 785 nm. However, the discrimination of liquid whole blood in a vacuum blood tube using Raman spectroscopy, which is a form of noncontact and nondestructive detection, has not been achieved. An excitation wavelength of 532 nm was chosen to avoid the fluorescent background of the blood tube, at the cost of reduced spectroscopic information and discrimination accuracy. To improve the accuracy and true positive rate (TPR) for human blood, a dual-model analysis method is proposed. First, model 1 was used to discriminate human-unlike nonhuman blood. Model 2 was then used to discriminate human-like nonhuman blood from the “human blood” obtained by model 1. A total of 332 Raman spectra from 10 species were used to build and validate the model. A blind test and external validation demonstrated the effectiveness of the model. Compared with the results obtained by the single partial least-squares model, the discrimination performance was improved. The total accuracy and TPR, which are highly important for practical applications, increased to 99.1% and 97.4% from 87.2% and 90.6%, respectively.
© 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

Saturday, June 16, 2018

Abstract-Terahertz Streaking of Few-Femtosecond Relativistic Electron Beams


Lingrong Zhao, Zhe Wang, Chao Lu, Rui Wang, Cheng Hu, Peng Wang, Jia Qi, Tao Jiang, Shengguang Liu, Zhuoran Ma, Fengfeng Qi, Pengfei Zhu, Ya Cheng, Zhiwen Shi, Yanchao Shi, Wei Song, Xiaoxin Zhu, Jiaru Shi, Yingxin Wang, Lixin Yan, Liguo Zhu, Dao Xiang, and Jie Zhan


Streaking of photoelectrons with optical lasers has been widely used for temporal characterization of attosecond extreme ultraviolet pulses. Recently, this technique has been adapted to characterize femtosecond x-ray pulses in free-electron lasers with the streaking imprinted by far-infrared and terahertz (THz) pulses. Here, we report successful implementation of THz streaking for time stamping of an ultrashort relativistic electron beam, whose energy is several orders of magnitude higher than photoelectrons. Such an ability is especially important for MeV ultrafast electron diffraction (UED) applications, where electron beams with a few femtosecond pulse width may be obtained with longitudinal compression, while the arrival time may fluctuate at a much larger timescale. Using this laser-driven THz streaking technique, the arrival time of an ultrashort electron beam with a 6-fs (rms) pulse width has been determined with 1.5-fs (rms) accuracy. Furthermore, we have proposed and demonstrated a noninvasive method for correction of the timing jitter with femtosecond accuracy through measurement of the compressed beam energy, which may allow one to advance UED towards a sub-10-fs frontier, far beyond the approximate 100-fs (rms) jitter.
  • Figure
  • Figure
  • Figure
  • Figure
  • Figure
  • Figure
  • Figure

Friday, May 18, 2018

Abstract-Terahertz streaking of few-femtosecond relativistic electron beams



Lingrong Zhao, Zhe Wang, Chao Lu, Rui Wang, Cheng Hu, Peng Wang, Jia Qi, Tao Jiang, Shengguang Liu, Zhuoran Ma, Fengfeng Qi, Pengfei Zhu, Ya Cheng, Zhiwen Shi, Yanchao Shi, Wei Song, Xiaoxin Zhu, Jiaru Shi, Yingxin Wang, Lixin Yan, Liguo Zhu, Dao Xiang,  Jie Zhang,

https://journals.aps.org/prx/accepted/d8075K71A261f001129c7ce70c632d2221b6fd030

Streaking of photoelectrons with optical lasers has been widely used for temporal characterization of attosecond extreme ultraviolet pulses. Recently, this technique has been adapted to characterize femtosecond x-ray pulses in free-electron lasers with the streaking imprinted by far-infrared and Terahertz (THz) pulses. Here, we report successful implementation of THz streaking for time-stamping of an ultrashort relativistic electron beam of which the energy is several orders of magnitude higher than photoelectrons. Such ability is especially important for MeV ultrafast electron diffraction (UED) applications where electron beams with a few femtosecond pulse width may be obtained with longitudinal compression while the arrival time may fluctuate at a much larger time scale. Using this laser-driven THz streaking technique, the arrival time of an ultrashort electron beam with 6 fs (rms) pulse width has been determined with 1.5 fs (rms) accuracy. Furthermore, we have proposed and demonstrated a non-invasive method for correction of the timing jitter with femtosecond accuracy through measurement of the compressed beam energy, which may allow one to advance UED towards sub-10 fs frontier far beyond the ∼100 fs (rms) jitter.