Thursday, February 11, 2021

Abstract-Dielectric property measurements of corneal tissues for computational dosimetry of the eye in terahertz band in vivo and in vitro

 

Maya Mizuno, Hideaki Kitahara, Kensuke Sasaki, Masahiko Tani, Masami Kojima, Yukihisa Suzuki, Takafumi Tasaki, Yoshinori Tatematsu, Masafumi Fukunari, and Kanako Wake


 Schematic diagram of the setups of specimens for (a) ATR and (b) T-type dielectric constant measurement, and reflectance measurement systems for (c) vertical and (d) oblique incidences. The white arrow in the left x-y image of (c) indicates the position with the largest reflection signal.

https://www.osapublishing.org/boe/fulltext.cfm?uri=boe-12-3-1295&id=447535

The dielectric constant of the normal corneal tissue of a rabbit eye was obtained in vitro in the range from approximately 0.1 to 1 THz, and the drying process on the eye surface exposed to high-power terahertz waves was investigated by in vivo reflectance measurement using terahertz time-domain spectroscopy. When the rabbit eye was exposed to terahertz waves at 162 GHz for 6 min with an irradiation power of 360 or 480 mW/cm2, the reflectance temporally increased and then decreased with a temperature increase. Based on multiple-reflection calculation using the dielectric constant and anterior segment optical coherence tomography images, those changes in reflectance were attributed to drying of the tear and epithelium of the cornea, respectively. Furthermore, the drying progressed over a temperature increase of around 5°C under our exposure conditions. These findings suggest that the possibility of eye damage increases with the progress of drying and that the setting of the eye surface conditions can be a cause of disagreement between computational and experimental data of absorbed energy under high-level irradiation because reflectance is related to terahertz wave penetration in the eye tissue. The time-domain spectroscopic measurements were useful for the acquisition of the dielectric constant as well as for the real-time monitoring of the eye conditions during exposure measurement.

© 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

Monday, June 4, 2018

Abstract-Ocular Effects of Exposure to 40, 75, and 95 GHz Millimeter Waves



Masami Kojima, Yukihisa Suzuki, Kensuke Sasaki,  Masao Taki,  Kanako Wake,  Soichi  Watanabe, Maya Mizuno,  Takafumi Tasaki, Hiroshi Sasaki

https://link.springer.com/article/10.1007/s10762-018-0497-z

The objective of this study was to develop a model of ocular damage induced by 40, 75, and 95 GHz continuous millimeter waves (MMW), thereby allowing assessment of the clinical course of ocular damage resulting from exposure to thermal damage-inducing MMW. This study also examined the dependence of ocular damage on incident power density. Pigmented rabbit eyes were exposed to 40, 75, and 95 GHz MMW from a spot-focus-type lens antenna. Slight ocular damage was observed 10 min after MMW exposure, including reduced cornea thickness and reduced transparency. Diffuse fluorescein staining around the pupillary area indicated corneal epithelial injury. Slit-lamp examination 1 day after MMW exposure revealed a round area of opacity, accompanied by fluorescence staining, in the central pupillary zone. Corneal edema, indicative of corneal stromal damage, peaked 1 day after MMW exposure, with thickness gradually subsiding to normal. Three days after exposure, ocular conditions had almost normalized, though corneal thickness was slightly greater than that before exposure. The 50% probability of ocular damage (DD50) was in the order 40 > 95 ≈ 75 GHz at the same incident power densities.

Sunday, April 29, 2018

Abstract-Analysis of dermal composite conditions using collagen absorption characteristics in the THz range


Maya Mizuno, Noriko Yaekashiwa, and Soichi Watanabe

https://www.osapublishing.org/boe/abstract.cfm?uri=boe-9-5-2277

The absorption characteristics of the dermis were reviewed in the terahertz range from 0.2 to 2 THz. The absorption magnitude of the dermis was higher than that of the epidermis model owing to the inclusion of collagen fibers. The heat denaturation of the collagen and the decrease of water content in the dermis caused a decrease in the absorption magnitude of the dermis. We verified that the absorption magnitude of collagen sheets at 1 THz similarly decreased by nearly 43% upon the heat treatment at approximately 70° C. When the heat-treated sheet was used as a scaffold for cell culture, the average growth rate of the fibroblast increased. These findings suggest that variation in the ability of cell growth in the dermis can be predicted using the absorption of the collagen or the difference between the absorptions of dermis and water.
© 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

Monday, May 16, 2016

Abstract-Improvement of Measurement Resolution of Depth Distribution in Cross-Sectional Imaging Using Terahertz Wave



  1. TETSUO FUKUCHI1, 
  2. NORIKAZU FUSE1,
  3. MAYA MIZUNO2 and
  4. KAORI FUKUNAGA2
Version of Record online: 12 MAY 2016
DOI: 10.1002/ecj.11819
http://onlinelibrary.wiley.com/doi/10.1002/ecj.11819/abstract

Time-resolved reflection measurement using broadband, short terahertz pulses can provide cross-sectional images of dielectric materials at different depths. Low-frequency components which have responses over a wide time range may result in inclusion of spurious signals which arise from strong reflections at other depths. Model calculations showed that such spurious signals can be suppressed by application of a frequency filter of an appropriate center frequency. The effect of frequency filtering was investigated in cross-sectional imaging of an IC card. Cross-sectional images were obtained at depth intervals of 0.18 mm, which provided images at five different depth intervals. As a result of frequency filtering, spurious signals resulting from strong reflections at different depths could be reduced in intensity, which resulted in improvement of the measurement resolution of the depth distribution.

Wednesday, April 1, 2015

Abstract-Terahertz spectral change associated with glass transition of poly-ε-caprolactone




We measured absorption spectra of unidirectionally stretched poly-ε-caprolactone (PCL) film in a range from 0.3 to 3.6 THz at temperatures from 10 to 300 K. Several absorption peaks were observed, when the electric field of THz waves was set in directions parallel and perpendicular to the stretching direction. The absorption bandwidths became significantly broad at around 200 K and above at least in two specific peaks. This temperature is close to the glass transition temperature of PCL. Further, it is shown by quantum chemical calculations that all the peaks obtained experimentally originate in skeletal vibrations of PCL. Therefore, it has become clear that a specific feature appears in the THz absorption spectrum of PCL associated with its glass transition.

Monday, November 17, 2014

Abstract-Vibration Modes at Terahertz and Infrared Frequencies of Ionic Liquids Consisting of an Imidazolium Cation and a Halogen Anion





1 Advanced ICT Research Institute, National Institute of Information and Communications Technology, 588-2 Iwaoka, Kobe 651-2492, Japan2 Applied Electromagnetic Research Institute, National Institute of Information and Communications Technology, 4-2-1 Nukuikitamachi, Koganei, Tokyo 184-8795, Japan

Abstract: The terahertz and infrared frequency vibration modes of room-temperature ionic liquids with imidazolium cations and halogen anions were extensively investigated. There is an intermolecular vibrational mode between the imidazolium ring of an imidazolium cation, a halogen atomic anion with a large absorption coefficient and a broad bandwidth in the low THz frequency region (13–130 cm−1), the intramolecular vibrational modes of the alkyl-chain part of an imidazolium cation with a relatively small absorption coefficient in the mid THz frequency region (130–500 cm−1), the intramolecular skeletal vibrational modes of an imidazolium ring affected by the interaction between the imidazolium ring, and a halogen anion with a relatively large absorption coefficient in a high THz frequency region (500–670 cm−1). Interesting spectroscopic features on the interaction between imidazolium cations and halogen anions was also obtained from spectroscopic studies at IR frequencies (550–3300 cm−1). As far as the frequency of the intermolecular vibrational mode is concerned, we found the significance of the reduced mass in determining the intermolecular vibration frequency.

Thursday, June 19, 2014

Abstract-Topcoat Thickness Measurement of Thermal Barrier Coating of Gas Turbine Blade Using Terahertz Wave



  1. Tetsuo Fukuchi1, 
  2. Norikazu Fuse1,
  3. Mitsutoshi Okada2, 
  4. Takayuki Ozeki2,
  5. Tomoharu Fujii2, 
  6. Maya Mizuno3 and
  7. Kaori Fukunaga3
Article first published online: 19 JUN 2014
DOI: 10.1002/eej.22624
http://onlinelibrary.wiley.com/doi/10.1002/eej.22624/abstract
The topcoat thickness of thermal barrier coating (TBC) applied to a gas turbine blade was measured using terahertz waves. The refractive index of the topcoat was obtained by frequency analysis of the waves reflected from the topcoat surface and the interface between the topcoat and bondcoat. The surface roughness of the topcoat surface was considered for improving the accuracy of the refractive index calculation. The topcoat thickness was obtained from the refractive index and the time separation between the reflected waves. The validity of the method was confirmed using a TBC sample with variable topcoat thickness, and the obtained topcoat thickness was in agreement with measurement results using a contact thickness gauge. Error analysis showed that the measurement error of the topcoat thickness was about 3%. The method was applied to a gas turbine blade with TBC, and the measured topcoat thickness agreed with microscope observation results of the cross section to within 6%, which was within the range of measurement error. The effect of curvature of the gas turbine blade surface did not result in significant measurement error. The results showed that terahertz waves are effective for nondestructive measurement of the topcoat thickness of TBC applied to gas turbine blades.