Showing posts with label terahertz computed tomography. Show all posts
Showing posts with label terahertz computed tomography. Show all posts

Saturday, February 24, 2018

Abstract-Application of continuous-wave terahertz computed tomography for the analysis of chicken bone structure


Bin Li,  Dayong Wang,  Lu Rong; Changchao Zhai, Yunxin Wang,  Jie Zhao

https://www.spiedigitallibrary.org/journals/Optical-Engineering/volume-57/issue-2/023105/Application-of-continuous-wave-terahertz-computed-tomography-for-the-analysis/10.1117/1.OE.57.2.023105.short



Terahertz (THz) radiation is able to penetrate many different types of nonpolar and nonmetallic materials without the damaging effects of x-rays. THz technology can be combined with computed tomography (CT) to form THz CT, which is an effective imaging method that is used to visualize the internal structure of a three-dimensional sample as cross-sectional images. Here, we reported an application of THz as the radiation source in CT imaging by replacing the x-rays. In this method, the sample cross section is scanned in all translation and rotation directions. Then, the projection data are reconstructed using a tomographic reconstruction algorithm. Two-dimensional (2-D) cross-sectional images of the chicken ulna were obtained through the continuous-wave (CW) THz CT system. Given by the difference of the THz absorption of different substances, the compact bone and spongy bone inside the chicken ulna are structurally distinguishable in the 2-D cross-sectional images. Using the filtered back projection algorithm, we reconstructed the projection data of the chicken ulna at different projection angle intervals and found that the artifacts and noise in the images are strikingly increased when the projection angle intervals become larger, reflected by the blurred boundary of the compact bone. The quality and fidelity of the 2-D cross-sectional images could be substantially improved by reducing the projection angle intervals. Our experimental data demonstrated a feasible application of the CW THz CT system in biological imaging.
© 2018 Society of Photo-Optical Instrumentation Engineers (SPIE)

Saturday, March 29, 2014

Abstract-Review of Terahertz Tomography Techniques



Terahertz and millimeter waves penetrate various dielectric materials, including plastics, ceramics, crystals, and concrete, allowing terahertz transmission and reflection images to be considered as a new imaging tool complementary to X-Ray or Infrared. Terahertz imaging is a well-established technique in various laboratory and industrial applications. However, these images are often two-dimensional. Three-dimensional, transmission-mode imaging is limited to thin samples, due to the absorption of the sample accumulated in the propagation direction. A tomographic imaging procedure can be used to acquire and to render three-dimensional images in the terahertz frequency range, as in the optical, infrared or X-ray regions of the electromagnetic spectrum. In this paper, after a brief introduction to two dimensional millimeter waves and terahertz imaging we establish the principles of tomography for Terahertz Computed tomography (CT), tomosynthesis (TS), synthetic aperture radar (SAR) and time-of-flight (TOF) terahertz tomography. For each technique, we present advantages, drawbacks and limitations for imaging the internal structure of an object.

Wednesday, April 6, 2011

New Contract for Advanced Photonix


April 6, 2011 8:22 AM EDT

ANN ARBOR, Mich.--(BUSINESS WIRE)-- Advanced Photonix® company (NYSE Amex: API), announced today that it has shipped the second Computer Tomography (CT) accessory to NICT in Japan. Building upon its previously purchased T-Ray 4000®, NICT is expanding its base system capability, by incorporating a CT gantry with a 20” horizontal and a 12” vertical scanning capability.
About Computed Tomography
Computed Tomography (CT) is a powerful nondestructive evaluation technique for producing 2D and 3D cross-sectional images of an object using flat images. With its ability to facilitate internal inspection of the human body as well as manufactured components, x-ray CT has been utilized in many medical and industrial applications. In contrast to conventional x-rays which emit high energy radiation that require extreme safety standards and shielding, terahertz technology is safe and can be used as an alternative in many of those industrial applications, or applications where x-rays cannot be safely used. Key areas for terahertz CT scanning include flaw detection, failure analysis, assembly analysis, as well as art and archeology applications.
The Company’s state-of-the-art CT platform includes two new additional software modules for the T-Ray® Explorer program, the CT Acquisition Module and the CT Reconstruction Module. The CT Acquisition Module provides multiple sinogram data collection. Each sinogram represents the data for a single slice of the object. Once the sinogram images are collected, they must be converted into the cross-sectional image using a filtered back projection transform. This is performed within the CT Reconstruction Module. The fully integrated modules are straightforward and provide greater ease to the workflow process. Once the operator determines the parameters, the CT Reconstruction Module will perform batch reconstruction of the slice sinograms. Exporting the slices as a single multi-image TIFF allows for the assembly of the slices as a 3D model in many third party software packages.
Richard (Rick) Kurtz President and CEO of Advanced Photonix, Inc, stated, “Our latest CT software increases the effectiveness and inter-operability with third party software, making it easier for users to obtain internal three dimensional images. We expect this product to be broadly embraced with extensive use in the areas of non-destructive testing as well as art and archeology. In the study of antiquities, for example, traditional x-ray technology has the potential danger of affecting thermo-luminescence dating and requires the use of personal protective gear. The optional gantry and motion control system combined with our new CT software provide a powerful tool to the Art and Archeology world. More detailed information on the NICT archeology study at: http://cts.businesswire.com/ct/CT?id=smartlink&url=http://www.nict.go.jp/publication/shuppan/kihou-journal/journal-vol55no1/05-02.pdf&esheet=6673278&lan=en-US&anchor=http://www.nict.go.jp/publication/shuppan/kihou-journal/journal-vol55no1/05-02.pdf&index=2&md5=fa2bf9669cfc6a5f5b61735f7d1484f7”
About Advanced Photonix, Inc.
Advanced Photonix, Inc.® (NYSE Amex: API) is a leading supplier with a broad offering of optoelectronic products to a global customer base. We provide optoelectronic solutions, high-speed optical receivers and terahertz instrumentation for telecom, homeland security, military, medical and industrial markets. With our patented technology and state-of-the-art manufacturing we offer industry leading performance, exceptional quality, and high value-added products to our OEM customer base. For more information visit us on the web at http://cts.businesswire.com/ct/CT?id=smartlink&url=http://www.advancedphotonix.com&esheet=6673278&lan=en-US&anchor=www.advancedphotonix.com&index=3&md5=816f32d7a6d534b0beb8e0fd8a056052.
The information contained herein includes forward looking statements that are based on assumptions that management believes to be reasonable but are subject to inherent uncertainties and risks including, but not limited to, unforeseen technological obstacles which may prevent or slow the development and/or manufacture of new products; potential problems with the integration of the acquired company and its technology and possible inability to achieve expected synergies; obstacles to successfully combining product offerings and lack of customer acceptance of such offerings; limited (or slower than anticipated) customer acceptance of new products which have been and are being developed by the Company; and a decline in the general demand for optoelectronic products. API-G

Advanced Photonix, Inc.Richard Kurtz, (734) 864-5688IR@advancedphotonix.com
Source: Advanced Photonix, Inc.

THANKS TO MY FRIEND CALM ON THE IV BOARD FOR THIS LINK!

Tuesday, December 28, 2010

Terahertz Computed Tomography studies at NASA's Glenn Research Center using Advanced Photonix T-4000

An aerial view looking northeast towards Cleve...Image via Wikipedia
 MY NOTE: Thanks once again to bucktailjig on sharing this informative piece.




Glenn Research Center
Title: X-ray & Terahertz studies (including 3D Computed Tomography) for Complex Aerospace Structures (Flexible Path Vehicle TPS, Stirling Engine Heater Heads)
Center Point of Contact:  Don J. Roth, 216-433-6017, Donald.J.Roth@nasa.gov.   Other participants include Mr. Richard Rauser (Univ. of Toledo), Dr. Ali Abdul-Azia (Cleveland State University, and Ms. Solimar Reyes (Michigan State University).

Objectives:  Baseline and apply X-ray and Terahertz methods to aerospace structures of interest in NASA Exploration and Aeronautics programs for quality assessments. This will include 3D computed tomography (CT) for both X-ray and terahertz.  NASA GRC will have the only terahertz computed tomography capability at the Agency.  Additionally, further develop the ability to create 3D solid and finite element models from CT volume renderings utilizing state-of-the-art tools, and use the models for further engineering analyses of samples with true damage
Background: The Terahertz pulse-echo NDE method has proven very useful in the inspection of external tank foam, shuttle underbelly tiles, ceramic materials and certain composite materials.  In the proposed work, we intend to fully characterize the capabilities of first-generation terahertz computed tomography that was developed by Picometrix, Inc. under an SBIR development program. Of particular interest is the application of this technology to new thermal protection system materials being developed for the Flexible Path Vehicle Crew Module, and possibly non-conducting (e.g. thermoplastic) structural foams and seals.  
Although Terahertz CT is not expected to compete resolution-wise with state-of-the-art X-ray computed tomography, it can potentially be more applicable as an inspection tool for very low density materials such as the TPS materials (unless the TPS materials are treated with contrast-enhancing substances that contaminate them). Also terahertz CT can be applied to complex-shaped structures such as tubes where reflection-mode terahertz is not applicable. It is necessary to baseline terahertz CT capabilities in order to determine how it can be used, and whether it can be used post-test for reuse assessment of TPS materials.   Because of its non-ionizing radiation character, it is possible to consider the use of Terahertz CT in field/depot applications with no safety implications.  Additionally, the use of Terahertz CT to virtually slice structures, create 3d volume renderings, and develop solid and FE models that allow further modeling is desirable to explore.  Further work in this effort will involve 1) X-ray CT for super high resolution aerospace structure characterization with direct application to Stirling Engine Heater Head being developed at GRC for future space missions, and for characterization of composite materials being developed under the ACT program 2) X-ray CT comparison with Terahertz CT, 3) upgrading the NDEWIP software to 64-bit to handle gigabyte-sized data sets and 4) modeling the X-ray CT process using SimCT software or an extension of the CIVA X-ray module.
This work addresses IMMEDIATE needs in the Stirling Engine and Flexible Path Vehicle Thermal Protection System development program, and tackles inspection issues with novel methods related to future space components including thermal protection systems (TPS), composite materials, and nickel-based superalloy materials for the next-generation space nuclear power systems
Technical Methodology/Approach:  A 3-year effort includes the following tasks:
  1. Baseline basic capabilities of Terahertz CT against X-ray CT for the same phantoms, standards, or other samples including assessing MMOD damage for actual thermal protection system materials and other aerospace structure materials.
  2. Apply X-ray CT to ACT composites, Stirline Engine Heater Heads and other aerospace structures for assessment of cracks, inclusions, ply waviness and other flaw conditions.  Up to 200 heater heads will be examined and hundreds of composite samples will be examined during this period.
  3. Develop 3d Volume Renderings and, subsequently, develop solid models and finite element models from such renderings.
  4. Perform thermal and/or mechanical load modeling utilizing the solid and FE models developed from the volume renderings, and utilize for NDE modeling (SimCT - see task 6), in a demonstration project to show how Terahertz CT and X-ray CT can be used in engineering capacity.
  5. Upgrade NDEWIP software to 64-bit cpability for batch pre-processing, visualization, and analysis of gigabyte-sized data sets.
  6. Model the X-ray CT process and compare with experimental results for model validation, inspection optimization, and better understanding of experimental results using SimCT or extension of CIVA X-ray module.
  7. Complete reports including final report for NNWG secure website.
Customers:  This work will support initiatives in the Exploration and Aero programs at NASA.  Flexible Path Crew Vehicle and Stirling Engine are the primary customers with Stirling engine providing significant co-funding (200K).
Metrics: Progress on samples tested, slice images and volume renderings computed, models developed, NDEWIP software upgrade process, thermal and/or mechanical load modeling results from the volume renderings.  Reports written.
Products: Reports on testing and simulation.  Software upgrades.  System upgrades.
Schedule/Milestones:
  • Years 1-3:  Baseline basic capabilities of Terahertz CT against X-ray CT for the same phantoms, standards, or other samples including thermal protection system materials and non-conducting aerospace structure materials such as forms.  Apply X-ray CT to aerospace structures (Flexible Path Vehicle TPS, Stirline Engine Heater Head, ACT composites) for characterization.  Upgrade NDEWIP software to 64-bit capability and debug/test.  Model X-ray CT process and compare with experimental results. (10/10 - 9/13)
  • Year 2:  For test cases, create 3d Solid and Finite element models from 3d Volume Renderings for both Terahertz and X-ray CT.  Perform thermal/mechanical load modeling utilizing the actual models developed from the methods' renderings. (10/11 - 9/12)
  • Year 3:  Complete reports (e.g. NASA TMs and/or journal articles) from the above tasks.  Complete final report for NNWG secure website posting. (10/12 - 9/13)
Status & Accomplishments as of October 30, 2010:  
  • Terahertz tomography system has been received in-house and extensive experiments were performed this summer by a Ph.D. candidate from Michigan State, Ms. Solimar Reyes.  A NASA TM and journal article
  • Extensive X-ray CT ensued on many different components from many different NASA programs and departments.  Primarily ACT (Advanced Composites Technology) and ASC (Advanced Stirling Converter) programs.
  • Initial phase of using X-ray CT data in engineering capacity has been started.  X-ray CT slice data for NASA thermal protection system material was segmented using multiple methods in order to form finite element models that could be used for further physical modeling.  A NASA TM is in preparation detailing this effort.
  • Alpha version of 64-bit NDEWIP has been developed using LabVIEW 2009.  99% of the code works but various features do not port to 64-bit.  We are developing workarounds for these.
  • A procurement has been placed for X-ray CT software simulation development with the CEA.  This software will build upon the CIVA X-ray Simulation program.
Key Facilities:                                                                                         
·         Xray CT facility, bldg. 6 – Rm. 11
·         THz CT facility
, bldg. 6 – Rm. 6 (new facility)
·         Finite Element Modeling Station, bldg. 6, Rm. 118

Enhanced by Zemanta