Showing posts with label microfluidics. Show all posts
Showing posts with label microfluidics. Show all posts

Wednesday, March 21, 2018

Abstract-Design Considerations for Integration of Terahertz Time-Domain Spectroscopy in Microfluidic Platforms



Rasha Al-Hujazy, Christopher M. Collier,



http://www.mdpi.com/2304-6732/5/1/5

Microfluidic platforms have received much attention in recent years. In particular, there is interest in combining spectroscopy with microfluidic platforms. This work investigates the integration of microfluidic platforms and terahertz time-domain spectroscopy (THz-TDS) systems. A semiclassical computational model is used to simulate the emission of THz radiation from a GaAs photoconductive THz emitter. This model incorporates white noise with increasing noise amplitude (corresponding to decreasing dynamic range values). White noise is selected over other noise due to its contributions in THz-TDS systems. The results from this semiclassical computational model, in combination with defined sample thicknesses, can provide the maximum measurable absorption coefficient for a microfluidic-based THz-TDS system. The maximum measurable frequencies for such systems can be extracted through the relationship between the maximum measurable absorption coefficient and the absorption coefficient for representative biofluids. The sample thickness of the microfluidic platform and the dynamic range of the THz-TDS system play a role in defining the maximum measurable frequency for microfluidic-based THz-TDS systems. The results of this work serve as a design tool for the development of such system

Tuesday, April 4, 2017

Abstract-Terahertz artificial material based on integrated metal-rod-array for phase sensitive fluid detection



Borwen You, Ching-Yu Chen, Chin-Ping Yu, Tze-An Liu, Toshiaki Hattori, and Ja-Yu Lu

https://www.osapublishing.org/oe/abstract.cfm?uri=oe-25-8-8571

A terahertz artificial material composed of metal rod array is experimentally investigated on its transmission spectral property and successfully incorporated into microfluidics as a miniaturized terahertz waveguide with an extended optical-path-length for label-free fluidic sensing. Theoretical and experimental characterizations of terahertz transmission spectra show that the wave guidance along the metal rod array originates from the resonance of transverse-electric-polarized waves within the metal rod slits. The extended optical path length along three layers of metal-rod-array enables terahertz waves sufficiently overlapping the fluid molecules embedded among the rods, leading to strongly enhanced phase change by approximately one order of magnitude compared with the blank metal-parallel-plate waveguide. Based on the enhanced phase sensitivity, three kinds of colorless liquid analytes, namely, acetone, methanol, and ethanol, with different dipole moments are identified in situ using the metal-rod-array-based microfluidic sensor. The detection limit in molecular amounts of a liquid analyte is experimentally demonstrated to be less than 0.1 mmol, corresponding to 2.7 μmol/mm2. The phase sensitive terahertz metal-rod-array-based sensor potentially has good adaptability in lab-chip technology for various practical applications, such as industrial toxic fluid detection and medical breath inspection.
© 2017 Optical Society of America

Sunday, June 5, 2016

Abstract-Microfluidic Devices for Terahertz Spectroscopy of Live Cells Toward Lab-on-a-Chip Applications



 1
,
  1
,
  2
,
  2
,
  3
,
  4
 and
  1,* 

1 Department of Electrical and Computer Engineering, University of Arizona, Tucson, AZ 85721, USA2 Department of Biomedical Engineering, Pennsylvania State University, University Park, PA 16802, USA3 WiseWear Corporation, New York, NY 10018, USA4 College of Pharmacy, University of Arizona, Tucson, AZ 85721, USA
* Author to whom correspondence should be addressed.
THz spectroscopy is an emerging technique for studying the dynamics and interactions of cells and biomolecules, but many practical challenges still remain in experimental studies. We present a prototype of simple and inexpensive cell-trapping microfluidic chip for THz spectroscopic study of live cells. Cells are transported, trapped and concentrated into the THz exposure region by applying an AC bias signal while the chip maintains a steady temperature at 37 °C by resistive heating. We conduct some preliminary experiments on E. coli and T-cell solution and compare the transmission spectra of empty channels, channels filled with aqueous media only, and channels filled with aqueous media with un-concentrated and concentrated cells.