Abstract-Methods for registering and calibrating in vivo terahertz images of cutaneous burn wounds



Priyamvada Tewari, James Garritano, Neha Bajwa, Shijun Sung, Haochong Huang, Dayong Wang, Warren Grundfest, Daniel B. Ennis, Dan Ruan, Elliott Brown, Erik Dutson, Michael C. Fishbein, and Zachary Taylor

Fig. 1 Burn zones organize as concentric like shells in the depth are hypothesized to appear as projections of the shells on the surface. Skin layers denoted A, B, C and damage zones denoted 1, 2, 3, 4. (a) Cross-sectional view: damage from superficial thickness wounds are limited primarily to the stratum corneum and epidermis, partial thickness burn wounds extend into the epidermis, and full thickness wounds extend into deep dermis. (b) Isometric view providing orientation between (a) and (c). (c) Top down view: The damage zones, and thus variations in surface TWC should present as regions concentric with the center.


https://www.osapublishing.org/boe/abstract.cfm?uri=boe-10-1-322

A method to register THz and visible images of cutaneous burn wounds and to calibrate THz image data is presented. Images of partial and full thickness burn wounds in 9 rats were collected over 435 mins. = 7.25 hours following burn induction. A two-step process was developed to reference the unknown structure of THz imaging contrast to the known structure and the features present in visible images of the injury. This process enabled the demarcation of a wound center for each THz image, independent of THz contrast. Threshold based segmentation enabled the automated identification of air (0% reflectivity), brass (100% reflectivity), and abdomen regions within the registered THz images. Pixel populations, defined by the segmentations, informed unsupervised image calibration and contrast warping for display. The registered images revealed that the largest variation in THz tissue reflectivity occurred superior to the contact region at ~0.13%/min. Conversely the contact region showed demonstrated an ~6.5-fold decrease at ~0.02%/min. Exploration of occlusion effects suggests that window contact may affect the measured edematous response.
© 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

Saturday, February 25, 2017

Terahertz Imaging and Sensing for Ophthalmic Evaluation of Corneal Edema and Dystrophies


Speaker: Shijun Sung 
Affiliation: Ph.D. Candidate, UCLA
http://www.ee.ucla.edu/events/terahertz-imaging-and-sensing-for-ophthalmic-evaluation-of-corneal-edema-and-dystrophies/
Abstract:  In the span of electromagnetic wave band from microwave to X-rays, the biological tissue-light interaction at the terahertz (THz) wavelength band (λ ~ 3mm – 30um) is particularly unique for two reasons. First, the THz band retains a large dielectric constant for water from the microwave region while having shorter wavelengths for imaging applications with < 1mm resolution. Second, scattering from typical soft tissue structures (cells, collagen matrix, etc.) is largely mitigated in the THz band, unlike in higher-frequency bands (IR band and up). Using this balance of properties, our study applies THz sensing to study diseases and conditions that compromise our body’s ability to balance water in tissues.
     This study focuses on developing a new medical imaging technology using terahertz (THz) frequency wave for precise tissue water content measurement and imaging of cornea, which is a critical refractive and protective component of the eye. In ophthalmology, most corneal disorders such as Fuchs’ endothelial dystrophy (corneal hydration mal-regulation), keratoconus (irregularly shaped cornea), and pseudophakic bullous keratopathy (corneal graft rejection) result in corneal edema, leading to chronic vision impairment if left untreated. Reliable corneal tissue water content (CTWC) measurement can help with early diagnosis and intervention for corneal diseases and provide a better understanding of the formation, progression of corneal disorders.
     This study developed a novel terahertz (THz) remote-sensing technique that measures absolute CTWC and have potential to be practically implemented in the clinical setting. The presentation will discuss development of a novel ophthalmic THz imaging system for completely non-contact, all normal incidence imaging of corneal surface. The imaging system employs wavelength independent quasioptical design that achieves 1.4 mm spatial resolution at 650GHz. THz corneal hydration sensing capability with this imager is demonstrated in in vivo rabbit model, showing onset of the acute corneal edema from endothelial damage, in the first THz imagery of living cornea ever captured. The imaging system is currently used in the initial clinical trial for healthy and diseased cornea of patients with corneal graft and corneal dystrophies.
Biography:  Shijun Sung is a doctoral student working with Prof. Warren Grundfest on the development of terahertz (THz) imaging and sensing method for applications in medical imaging. Shijun completed his B.S., M.S. in Electrical Engineering at UCLA. His doctoral research focuses on novel quasioptical imaging system development for diagnostic imaging of corneal dystrophies.

Wednesday, December 28, 2016

Abstract-Non-invasive terahertz imaging of tissue water content for flap viability assessment




Neha Bajwa, Joshua Au, Reza Jarrahy, Shijun Sung, Michael C. Fishbein, David Riopelle, Daniel B. Ennis, Tara Aghaloo, Maie A. St. John, Warren S. Grundfest, and Zachary D. Taylor
https://www.osapublishing.org/boe/abstract.cfm?uri=boe-8-1-460

Accurate and early prediction of tissue viability is the most significant determinant of tissue flap survival in reconstructive surgery. Perturbation in tissue water content (TWC) is a generic component of the tissue response to such surgeries, and, therefore, may be an important diagnostic target for assessing the extent of flap viability in vivo. We have previously shown that reflective terahertz (THz) imaging, a non-ionizing technique, can generate spatially resolved maps of TWC in superficial soft tissues, such as cornea and wounds, on the order of minutes. Herein, we report the first in vivo pilot study to investigate the utility of reflective THz TWC imaging for early assessment of skin flap viability. We obtained longitudinal visible and reflective THz imagery comparing 3 bipedicled flaps (i.e. survival model) and 3 fully excised flaps (i.e. failure model) in the dorsal skin of rats over a postoperative period of 7 days. While visual differences between both models manifested 48 hr after surgery, statistically significant (p < 0.05, independent t-test) local differences in TWC contrast were evident in THz flap image sets as early as 24 hr. Excised flaps, histologically confirmed as necrotic, demonstrated a significant, yet localized, reduction in TWC in the flap region compared to non-traumatized skin. In contrast, bipedicled flaps, histologically verified as viable, displayed mostly uniform, unperturbed TWC across the flap tissue. These results indicate the practical potential of THz TWC sensing to accurately predict flap failure 24 hours earlier than clinical examination.
© 2016 Optical Society of America

Monday, November 2, 2015

Abstract-THz polarization difference imaging of aqueous targets


Shijun Sung; Neha Bajwa; Lucia Ramirez; Warren Grundfest; Zachary Taylor

http://spie.org/Publications/Proceedings/Paper/10.1117/12.2189318

This paper describes the basic design, implementation, and testing of a polarization difference imaging system for use on aqueous targets. The ultimate performance limitation of THz imaging in many active areas of research is clutter from surface geometry. While the signal to nose ratio (SNR) of standard THz imaging systems is quite large, the signal to clutter ratio (SCR) often faced in an imaging application is orders of magnitude lower and, in many cases, lower than the contrast to noise (CNR) resulting in imagery where the contrast mechanism of interest does not significantly contribute to the overall observed contrast. To overcome these limitations we develop a system that uses a circularly polarized source and linearly polarized detectors to acquire images of transverse electric (TE) and transverse magnetic (TM) reflectivities of the target over the same field of view. Geletin based tissue mimicking phantoms are fabricated with spatially varying water content and modified with a range of surface topologies and surface roughness. TE and TM images are combined to yield self-calibrated clutter-suppressed images. The resulting image indicates that the imaging field clutter affected both polarization channels nearly equally allowing the system to resolve differences in phantom water content. This design is a step toward windowless THz imaging capability critical for clinical translation where patient imaging is dominated by clutter.

Tuesday, October 20, 2015

Abstract-Exploration of the effects of burn parameters on THz wound imaging


Neha Bajwa; Shijun Sung; Michael Fishbein; Warren S. Grundfest; Zachary D. Taylor

http://spie.org/Publications/Proceedings/Paper/10.1117/12.2189295

The high contrast resolution afforded by terahertz (1 THz = 1012 Hz) imaging of physiologic tissue continues to drive explorations into the utility of THz technology for burn wound detection. Although we have previously reported the use of a novel, reflective THz imaging technology to sense spatiotemporal differences in reflectivity between partial and full thickness burn wounds, no evidence exists of a one-to-one correlation between structural damage observed in histological assessments of burn severity and THz signal. For example, varying burn induction methods may all result in a common burn wound severity, however, burn features observed in parallel THz imagery may not be identical. Successful clinical translation of THz technology as a comprehensive burn guidance tool, therefore, necessitates an understanding of THz signal and its relation to wound pathophysiology. In this work, longitudinal THz imagery was acquired with a quartz (n = 2.1, 500 μm) window of cutaneous wounds induced with the same brand geometry and contact pressure but varying contact times (5, 7, and 10 seconds) in in vivo, pre-clinical rat models (n=3) over a period of 3 days. Though all burn wounds were evaluated to be deep partial thickness with histology, THz contrasts observed for each burn contact time were intrinsically unique. This is the first preliminary in vivo evidence of a many-to-one relationship between changes in THz contrast and burn severity as ascertained by histology. Future large-scale studies are required to assess whether these observed changes in THz contrast may be interpreted as physiological changes occurring over time, morphometric changes related to anatomical change, or electromagnetic changes between dielectric substrate windows and the underlying tissue.