Okayama University Research: Technology to Rapidly Detect Cancer Markers for Cancer Diagnosis



Breast-cancer cells bound to aptamers have a different terahertz response than freestanding aptamers. This notion can be exploited to detect, with high sensitivity, breast-cancer cells.
https://finance.yahoo.com/news/okayama-university-research-technology-rapidly-053400536.html

OKAYAMA, Japan, April 29, 2019 /PRNewswire/ -- Researchers at Okayama University report in the journal Sensors and Actuators B: Chemical that terahertz radiation can be used to rapidly detect makers for breast-cancer cells. The scientists present a technique that makes use of the binding properties of aptamers, synthetic organic molecules acting as probes for cancer cells.
Breast cancer is the most common cancer in women. Detecting it in time is crucial for treatment to be successful. X-ray screening (mammography) is the standard detection technique but is not without risk as it involves exposure of a patient to ionizing radiation. Another approach for detecting breast cancer cells is based on terahertz (THz) radiation, which is sensitive to polar molecules like water — normal and cancer tissues do not have the same water content. Associate Professor Toshihiko Kiwa (Okayama University, Japan) and Professor Tsuneyuki Ozaki (INRS : Institut national de la recherche scientifique, Canada) and colleagues have now discovered a way to increase the sensitivity of THz radiation for the detection of makers of breast cancer cells, implying that 'THz chemical microscopy' could become a powerful alternative screening technique.
The key principle underlying the method of Associate Professor Kiwa and colleagues is that cancer and normal breast cells bind and don't bind, respectively, to certain molecules known as aptamers.  The aptamers consist of (single-stranded) DNA or RNA fragments; they have a high affinity for particular molecules — in the experiments of the team of Associate Professor Kiwa, these molecules were breast cancer cells.
The experimental setup of the researchers involved a sensing plate, consisting of a sapphire substrate, and silicon and silicon dioxide thin films. The aptamers were fixed to the top layer.  Irradiating the plate with a specific laser creates charge carriers, the motion of which generates electromagnetic radiation in the THz range. The precise THz response depends, however, on whether the aptamers are 'freestanding' (no cells attached) or not (breast-cancer cells attached).  The former corresponds to the situation where the sample on the sensing plate only consists of normal cells; for the latter, the sample contains breast-cancer cells.
The scientists noted that the detection method is highly sensitive: the so-called 'limit of detection' was found to be as low as 1 cancer cell in 0.1 milliliter of sample. Moreover, a qualitative assessment of a sample seems possible, as the change in THz signal can be associated with the number of cancer cells per aptamer. Although further investigation on the latter association is needed, Associate Professor Kiwa and colleagues conclude that " the results obtained from this study can be the spark of new evolution in the detection of breast cancer."
Background
Mammography
Mammography is the procedure in which low-energy X-rays are used to screen the human breast for cancer. Although it is the standard technique for breast cancer detection, the use of X-rays implies exposure to ionizing radiation. Because there have also been cases of false positives (apparent detection of breast cancer in a healthy patient) and false negatives (missed detections), alternative detection methods are desired. Associate Professor Toshihiko Kiwa and Professor Tsuneyuki Ozaki and colleagues have now reported a promising detection technique, in which a tissue sample is investigated by terahertz (THz) radiation.
Aptamers
Aptamers are short DNA or RNA molecules, or molecules built from peptides, that can bind to specific molecules. Associate Professor Kiwa and colleagues used the binding properties of two aptamers, mammaglobin B1 (MAMB1) and mammaglobin A2 (MAMA2). These aptamers bind to proteins (mammaglobin B and mammaglobin A, respectively) that are overexpressed in typical breast-cancer cells.  Attached to a special engineered sensing plate, freestanding and bound (to cancer cells) aptamers have a different response to terahertz radiation. This difference can be used to distinguish a tissue sample with breast-cancer cells from a sample with only normal cells.
Caption
Breast-cancer cells bound to aptamers have a different terahertz response than freestanding aptamers. This notion can be exploited to detect, with high sensitivity, breast-cancer cells.
Reference
Eman M. Hassan, Ahmed Mohamed, Maria C. DeRos, William G. Willmore, Yuki Hanaoka, Toshihiko Kiwa, Tsuneyuki Ozaki. High-sensitivity detection of metastatic breast cancer cells via terahertz chemical microscopy using aptamers. Sensors & Actuators: B. Chemical, 287 (2019), 595–601.

Thursday, June 28, 2018

Okayama University Research: Measuring ion Concentration in Solutions for Clinical and Environmental Research


Schematic of the sensing plate when it is illuminated by the femtosecond laser. Inset is the microphotograph of the microsolution wells. (PRNewsfoto/Okayama University)
Okayama University researchers describe in the journal Optics Express the use of Terahertz (THz) chemical microscopy to measure the pH of water-based solutions with a volume as small as 16 nL. The findings are important to be able to measure pH concentrations in small-volume solutions for clinical and environmental analyses.

https://www.prnewswire.com/news-releases/okayama-university-research-measuring-ion-concentration-in-solutions-for-clinical-and-environmental-research-686667031.html


For clinical and environmental research and monitoring it is important to be able to measure pH concentrations in small-volume solutions. However, conventional systems used to measure the concentration of ions require the use of reference electrodes that end up reducing the volume of the solution, setting a limit on the minimum volume that it is possible to analyze.
Now, Dr. Toshihiko Kiwa and colleagues at the Graduate School of Natural Science and Technology in Okayama University, Japan, demonstrated the use of Terahertz (THz) chemical microscopy to measure the pH of water-based solutions with a volume as small as 16 nL. The results are published in Optics Express. This type of microscope has a sensing plate with patterned micro wells hosting the solution; an ultrafast laser pulse directed on the sensing plate generates a photocurrent with ultrafast modulation that, in turn, emits THz radiation into free space. Because the amplitude of the THz radiation depends on the concentration of ions in the micro wells, this method opens up the possibility of imaging the concentration of ions without the need of using electrodes. This enables the measurement of volumes of solution that would be too small for conventional methods.
The THz chemical microscope, which was developed by this same group in 2007, features a semiconducting (silicon) thin film mounted on a sapphire substrate that acts as the sensing plate. A layer of oxide naturally forms on the silicon film, providing an insulating layer between the silicon surface and the solution. The researchers added a resin on top of the oxide layer and used conventional photolithographic techniques to pattern micro wells in it, obtaining wells with a volume of 16 nL. They also optimized the laser pulses to stabilize the signal, and integrating this method into the microscope is part of the next steps the researchers intend to take.
Thinking about the future directions the team is interested to explore, the author says that "we will attempt the integration for multi-ion sensing and reducing the laser spot size to improve the accuracy of THz chemical microscopy."
About Okayama University 
Okayama University is one of the largest comprehensive universities in Japan with roots going back to the Medical Training Place sponsored by the Lord of Okayama and established in 1870. Now with 1,300 faculty and 13,000 students, the University offers courses in specialties ranging from medicine and pharmacy to humanities and physical sciences.
Okayama University is located in the heart of Japan approximately 3 hours west of Tokyo by Shinkansen.
Correspondence to 
Associate Professor Toshihiko Kiwa, Ph.D.
Advanced Electro Measurement Technology Laboratory,
Graduate School of Interdisciplinary Science and Engineering
in Health Systems, Okayama University,
3-1-1 Tsushimanaka, Kita-Ku, Okayama 700-8530, Japan
Further information
Okayama University
1-1-1 Tsushima-naka , Kita-ku , Okayama 700-8530, Japan
Public Relations and Information Strategy
E-mail: www-adm@adm.okayama-u.ac.jp
Website: http://www.okayama-u.ac.jp/index_e.html
Okayama Univ. e-Bulletin: http://www.okayama-u.ac.jp/user/kouhou/ebulletin/
About Okayama University (YouTube): https://www.youtube.com/watch?v=iDL1coqPRYI
Okayama University Image Movie (YouTube): https://www.youtube.com/watch?v=KU3hOIXS5kk

Reference
  
Toshihiko Kiwa, Tatsuki Kamiya, Taiga Morimoto, Kenji Sakai, And Keiji Tsukada. pH measurements in 16-nL-volume solutions using terahertz chemical microscopy. Optics Express, 26(7), 8232-8238, 2018.
Reference (Okayama Univ. e-Bulletin): Associate Professor Kiwa's team 
SOURCE Okayama University

Tuesday, March 18, 2014

TeTechS blog-Terahertz Emission Microscopy


http://www.tetechs.com/blog/

Posted by  on in Terahertz

In a terahertz time-domain spectroscopy, the spatial resolution is limited by the wavelength of the THz radiation, which is about 300μm at 1THz. To overcome this limitation, researchers at Okayama University (Okayama, Japan) have developed a laser-THz emission microscope (LTME) for non-destructive imaging of semiconductor devices. In this technique, the spatial resolution is limited by the shorter wavelength of the femtosecond laser that is used to generate the THz radiation. This microscope has a sensing plate made of a stack of Thin SiO2 (275 nm) and Si (170nm) layers deposited on a sapphire substrate. When a femtosecond laser hits the silicon layer from the substrate side, a THz pulse with the peak wavelength of 0.3 THz is generated and emitted from this plate. When a chemical reaction happens on the sensing plate (active area is 10 mm2), the chemical/electrical potential of the sensing plate changes accordingly. This leads to a change in the magnitude of the local field and as a result the intensity of the generated THz pulse. Scanning the pump laser across the sensing plate produces an image of the respective chemical reaction. Currently this technique has a spatial resolution of 50μm which can be improved by optimizing the femtosecond laser focusing.  In addition, this system can be used to perform label-free immunoassays, in which the system sensitivity is independent of the sample material’s molecular weight.  An Immunoassay is a biochemical test that measures the presence or concentration of a macromolecule in a solution through the use of an antibody or immunoglobulin. In a conventional method immunoassays employ a variety of different labels to allow for detection of antibodies and antigens. Labels are typically chemically linked or conjugated to the desired antibody or antigen.
b2ap3_thumbnail_fig2_20140313-190407_1.jpg

Monday, March 3, 2014

TERAHERTZ IMAGING: Terahertz microscope images chemical reactions



Using an imaging process they call laser-terahertz emission microscopy (LTEM), researchers at Okayama University (Okayama, Japan) have developed a terahertz chemical microscope (TCM) that images chemical reactions with higher spatial resolution than conventional terahertz imaging methods.1 That is, the TCM spatial resolution is not limited by the wavelength of the terahertz radiation generated, but instead is limited by the much shorter wavelength of the femtosecond laser used to generate the terahertz radiation.
Terahertz sensing
The reactive portion of the TCM consists of thin silicon dioxide (SiO2) and silicon (Si) layers (275 and 170 nm thick, respectively) on a sapphire substrate. When light from a 790-nm-emitting femtosecond laser operated with a 100 fs pulse width and an 82 MHz pulse repetition rate travels through the sapphire substrate and strikes the Si-based films, terahertz radiation with a peak wavelength of approximately 0.3 THz is generated and radiated to a low-temperature-grown gallium arsenide (GaAs) photoconductive antenna sensor that works as the terahertz detector.
If a chemical reaction progresses on the 10 mm2 sensing plate above the film, chemical and/or electrical potential shifts at the surface of the plate cause a change in the local field magnitude and a corresponding variation in the amplitude of the generated terahertz pulse. And because the terahertz pulse contains information about the reaction at the precise location of the laser that created the pulse, scanning the laser across the sensing plate produces a map or image of the spatial details of the chemical reaction (see figure).
A photograph of the terahertz chemical microscope (TCM) sensing plate shows immobilized sensing polymer membranes for sodium (Na+) and potassium (K+) ions; the TCM image clearly indicates when the concentration of sodium ions in the water solution on the sensing plate was changed
A photograph of the terahertz chemical microscope (TCM) sensing plate (a) shows immobilized sensing polymer membranes for sodium (Na+) and potassium (K+) ions. The TCM image (b) clearly indicates when the concentration of sodium ions in the water solution on the sensing plate was changed from 10-4 mol/L to 10-1 mol/L.
Although the spatial resolution of the TCM is currently about 50 μm, this can be improved by optimizing the aperture of the objective lens that is used to focus the laser onto the sapphire substrate. Currently, a plano-convex lens with a diameter of 25.4 mm and focal length of 60 mm is used, where the spot size of the laser was approximately 3 mm.
Possible reactions
Currently, the TCM system can be used to detect changing concentration levels of ions in solution, or changes in immunoglobulin reactions. The researchers say that the label-free technique is even more sensitive than standardimmunoassays because the TCM process is not dependent on the molecular weight of the sample; for example, they have been able to detect molecules as small as biotin that are difficult to measure using conventional methods.
“Now, we are working toward realizing a ‘multi-omics’ platform using TCM for a next-generation medical diagnostic system,” says Toshihiko Kiwa, associate professor at Okayama University. Multi-omics (or multiomics) is defined as being applicable to multiple fields of study ending in the phrase ‘omics,’ such as genomics and proteomics. “We already developed the prototype TCM and sensing plates are ready to deliver to researchers in diverse research fields who are interested in screening and/or visualization of chemical or bioreactions,” Kiwa adds.
In addition to exploring TCM applications in medical diagnosis and materials research, the researchers are also developing fuel cells that will be mounted on the sensing chip so that catalytic reactions of their electrodes can be measured.
REFERENCE
1. T. Kiwa et al., “Imaging chemical reactions,” SPIE Biomedical Optics & Medical Imaging online (December 31, 2013).