TAS5500 Terahertz Powermeter
Calorimeter-type power meter achieves highly accurate absolute power
measurement of terahertz (THz) spatial beam with a measurement accuracy of
better than 8%
The TAS5500 powermeter draws on Advantest's
amassed proprietary terahertz analysis technology to deliver measurement
accuracy of > (+-) 8%, as calibrated against a primary standard based on the
10.6um standard set by Japan's AIST. It will be invaluable as a basic
measurement instrument to researchers in the fields of terahertz spectroscopy,
terahertz communications, and other R&D sectors.
Key Specifications
Calorimeter-type power meter achieves highly accurate absolute power measurement of terahertz (THz) spatial beam with a measurement accuracy of better than 8%
Optical input
|
10mm active diameter with manual shutter
|
||
Frequency range
|
0.3 – 10THz
|
||
Accuracy
|
11% or less 1) 2) (0.4 – 10THz)
|
||
Power range
|
100mW – 20uW
|
||
Response time (95%)
|
30 sec or less
|
||
Display
|
Readout software on user PC with USB-IF
?Supported OS: Windows7, 32/64bit, English/Japanese) |
||
Analysis software
function
|
Log, linear, statistic, trend graph display function
Remote control function by user application |
|
|
Operating environment
|
Temperature range?+10°C – +30°C
Relative humidity?80% or less?no condensation? |
|
|
Storage environment
|
Temperature range?-10°C – +50°C
Relative humidity?80% or less?no condensation? |
|
|
External dimensions,
mass
|
115(W) x 67(d) x 79(H)mm (sensor unit, protruding
parts not included?
900g or less(sensor unit? |
|
|
1)
Refering to band-enlarged Advantest's standard based on the national standard
of 10.6um, uncertainty 2?, for 6 months.
2)
Calibrated by 5mm beam at sensor center
*
Specifications may change without notification